Panels
A battened all-hardwood revetment panel combines the wall in a panel. Compare variants and determine separately how the panel connects to the posts.
Do not compare a separate plastic panel with a single hardwood board. Compare the complete construction that must resist the same soil and water pressure: panels, posts, waler, fixings, finishing and any anchoring.
Specifically looking for separate posts for Prolock? View Ø100 mm spruce posts in seven lengths and enquire about your quantities. For panels, choose the Sigma size and current price. To have the material selection checked, request a Prolock Sigma quote .
Short answer
Prolock Sigma combines plastic and timber for lighter water-retaining structures. Hardwood post-and-panel revetment forms the wall from boards or panels and supporting posts. Hardwood sheet piling forms a continuous, deeper earth-retaining wall. Suitability follows from load and construction, not preference alone.
A practical comparison brief
Prolock and hardwood can be used together: a Sigma wall combines plastic panels with timber components. This existing project estimates the same Sigma system with two post variants. It compares the post material within one system.
Price basis: 13 November 2026, including VAT. Materials only; transport and installation are excluded. These are historical project estimates, not a current quotation.
The quotation does not establish which post variant was ultimately installed. The project image and base estimate follow the spruce variant.
This source provides neither a materials list nor a total price for an entirely hardwood wall. The following details make a new quotation comparable: resolve the open points for both constructions using the same assumptions.
On narrow screens you can scroll the table sideways.
| Item | Known from this Sigma example | Check on the same basis for an entirely hardwood wall |
|---|---|---|
| Alignment | 30 m of bank; the illustration simplifies the alignment to a straight line. | Record the same 30 m, actual recesses, curves, corners and ends. |
| Wall | 60 Sigma panels measuring 0.50 × 1.50 m. | Choose a post-and-board construction or continuous sheet piling; establish profile, effective width, height and quantities. |
| Height and water | Top edge approximately 25–30 cm above water; water about 40 cm deep directly in front of the wall, deeper further away. | Use the same levels and retained height; assess total wall height and embedment depth. |
| Soil and loads | Soil conditions and structural equivalence have not been established. | Assess the same soil, earth and water pressures, surcharge loads and any wave action. |
| Posts | 60 internal posts; the spruce base variant is Ø100 mm × 2.50 m. | Specify species, cross-section, length and layout by design; 60 posts is not a universal requirement. |
| Waler and top edge | 30 m of hardwood waler and 30 m of hardwood capping board are included. | Include the same finish level, quantities, joints and cutting plan. |
| Anchoring and fixings | 20 anchor rods and 20 anchor posts; required connections are in the materials list. | Specify required anchoring, connections, steel/coating and quantities. |
| Complete cost | Both totals cover Sigma with different posts; neither prices an entirely hardwood wall. | Cost all components, assessment, transport, installation and any removal separately. |
The estimate establishes neither structural equivalence nor suitability or service life. An entirely hardwood wall can only be compared on price once its complete construction has been specified for the same site.
Comparison matrix
The table is an orientation guide. Final panel length, post spacing, embedment depth and anchoring remain project specific.
| Route | Visible wall | Supporting structure | Useful first question | DamwandDirect route |
|---|---|---|---|---|
| Prolock Sigma | Plastic panels with system finishing components. | Longer, project-specific posts and additional components if needed. | Does a lighter revetment suit the load? | Sigma system and product scope |
| Hardwood post-and-panel | Boards or panels against or between posts. | Posts, walers, fixings and any anchoring. | Which board, post and waler specification forms one system? | Select products |
| Hardwood sheet piling | Continuous hardwood sheet-pile boards. | Embedment depth, waler and any anchoring according to project loads. | Is a deeper, continuous earth-retaining wall required? | View the sheet piling family |
Plastic route
Prolock is Profextru's product brand. The manufacturer distinguishes Sigma for lighter water-retaining structures, Nova for plastic post-and-panel construction and Omega for heavier sheet-pile constructions. DamwandDirect is a retailer, not the manufacturer.
Manufacturer statements about service life, circularity or performance remain manufacturer claims. We do not use them here as universal guarantees for every project, because installation, other structural components and conditions differ by situation.
Compare Sigma, Nova and OmegaHardwood route
Hardwood can be used for posts, boards, walers and sheet-pile boards. A timber species or certification mark on one product does not automatically apply to all structural components. Check the exact product page and its source status.
DamwandDirect does not infer FSC claims or other certification where these have not been verified for the product concerned. A TLV designation on a hardwood product applies to that stated product entry, not automatically to any alternative.
View current hardwood familiesFrom material to product
Compare species, cross-section, length and finish for each component. The product families below are not a prescribed combination; the required dimensions follow from project assessment.
A battened all-hardwood revetment panel combines the wall in a panel. Compare variants and determine separately how the panel connects to the posts.
For example, view the 80 × 80 mm hardwood post and the Ø60 mm treated round pine post. Their material, cross-section and treatment differ. They are therefore not interchangeable without assessment or suitable for every waterfront.
Compare the product details for hardwood beams of 50 × 100 mm and 80 × 150 mm, or the 150 × 200 mm beam, waler or capping timber. Function, span and connections determine which cross-section should be investigated; a larger size is not a structural calculation.
Decision questions
Record retained height, water level and use behind the bank. A lawn, storage area and traffic zone impose different loads.
Soil affects embedment depth, posts and installation method. Unknown or soft soil is a reason not to rely on a standard size.
Corners, curves, ends, height transitions and existing structures determine the profiles and connections required.
Access, working space, equipment and safety can limit feasible lengths, weights and installation sequence.
Check product sources, exact variant, any certification, structural assessment and location-specific consent before the final order.
Use the same materials scope and the same transport and installation boundaries for both options. Only then are quotes substantively comparable.
Go to the cost breakdownFrequently asked questions
No. A fair comparison covers the complete construction, application limits, maintenance situation, origin, installation and project-specific load. A general materials claim does not replace a design or product specification.
Not always. Hardwood post-and-panel revetment consists of boards or panels with a supporting post-and-waler construction. Continuous hardwood sheet piling uses interlocking sheet-pile boards as a continuous wall. Both require project-specific embedment depth and supporting structure.
That cannot reliably be determined from panel material alone. Compare the same route length and load, including posts, walers, fixings, finishing, transport, assessment and installation. Current product prices are only part of that comparison.
DamwandDirect can check a product enquiry and materials specification, but webshop advice is not a structural calculation. Greater or uncertain loading requires project-specific assessment by an appropriate expert.
From comparison to enquiry
Provide the same length, height, water levels, soil knowledge, loads, corners, access and photos for every option. This makes differences between materials lists understandable and avoids comparing incomplete packages.
Verifiable sources
The links below support the factual information. Manufacturer sources remain clearly identified; check local rules with the competent authority. Linked external original sources are in Dutch and government sources concern the Netherlands.
Official manufacturer source for Prolock Sigma positioning, system construction and application context.
Official manufacturer source for Nova construction with plastic panels and timber or hardwood posts.
Official manufacturer source for Omega positioning in heavier water-retaining structures.
Source for current sizes, price status, availability and ordering or quote route for each product variant.
Dutch government explanation of possible permit, notification and other duties for sheet piling and revetment.